Unox Stainless Steel Compressor Normally Closed Solenoid Valve (0.5–16 BAR)
- 100% genuine product
- Corporate invoice
- In Karaköy, Istanbul since 1976
- Free technical consulting
Stainless Steel Compressor Normally Closed Solenoid Valve
What is a Stainless Steel Compressor Solenoid Valve?
A stainless steel compressor solenoid valve is a component that controls the airflow of a compressor. This valve is used to manage the air compression process and regulate air pressure. It is generally controlled by an electromagnetic force and can open or close the air passage. This allows the compressor system to maintain air pressure in a controlled manner, increasing or decreasing it as needed.
Where is a Stainless Steel Compressor Solenoid Valve Used?
Stainless steel compressor solenoid valves are widely used in air compression systems. For example, they can be found in home air conditioning units, air regulator systems, and automotive air conditioning systems. They are also used in air compressors and certain pneumatic systems.
Solenoid valves are manufactured in two types: normally closed (the valve opens when the coil is energized) and normally open (the valve closes when the coil is energized).
Normally Closed Operation
A normally closed solenoid valve initially prevents fluid flow. When electric current is applied to the coil, the coil moves the plunger upward, opening the orifice. This allows the fluid under high pressure to quickly exit through the bypass. As a result, the internal pressure drops rapidly, creating a pressure difference. This difference overcomes the diaphragm spring force, lifting the diaphragm and allowing fluid to pass, thus opening the valve. All of this happens in a very short time. Our product is designed for maximum efficiency.
General Specifications
- Seal: Viton
- Coil housing: Stainless steel
- Body: AISI 316 Stainless Steel
- Plunger: Stainless steel
- Temperature: -10 / +150 °C
- Coil: Socket type
Recommendations
- Install the valve with the coil facing upward.
- Use filters, such as dirt traps, before the solenoid valve in the system.
- For high-temperature applications, request more durable diaphragm and seal materials when ordering.
Selection Considerations for Solenoid Valves
- The coil must match the operating voltage (AC/DC) and be properly protected.
- Minimum and maximum pressure of the system is critical for valve selection.
- The nature and temperature of the fluid directly affect the valve selection.
- Ensure the fluid direction matches the arrow on the valve body during installation.
- Since the solenoid valve does not function as a check valve, fluid may flow backward under reverse pressure. In such cases, installing a check valve downstream is recommended.
- The piping where the valve is installed must be free of debris.
Dimensions and Specifications
| Size | Model | Orifice (mm) | Pressure |
|---|---|---|---|
| 1/8" | IKM 1900 | 1 | 100 Bar |
| 1/8" | IKM 1900 | 1.8 | 60 Bar |
| 1/8" | IKM 1900 | 2.5 | 40 Bar |
| 1/8" | IKM 1900 | 3 | 20 Bar |
| 1/8" | IKM 1900 | 4 | 10 Bar |
| 1/8" | IKM 1900 | 5 | 5 Bar |
| 1/8" | IKM 1900 | 8 | 1 Bar |
| 1/4" | IKM 1901 | 1 | 100 Bar |
| 1/4" | IKM 1901 | 1.8 | 60 Bar |
| 1/4" | IKM 1901 | 2.5 | 40 Bar |
| 1/4" | IKM 1901 | 3 | 20 Bar |
| 1/4" | IKM 1901 | 4 | 10 Bar |
| 1/4" | IKM 1901 | 5 | 5 Bar |
| 1/4" | IKM 1901 | 8 | 1 Bar |
| 3/8" | IKM 1902 | 12 | 0.5-16 Bar |
| 1/2" | IKM 1903 | 14 | 0.5-16 Bar |
| 3/4" | IKM 1904 | 16 | 0.5-16 Bar |
| 1" | IKM 1905 | 17 | 0.5-16 Bar |
Frequently Asked Questions
Install the solenoid valve with the coil on top and the arrow on the body pointing in the flow direction. A strainer before the valve extends the life of the seal and diaphragm.
Choose a 220 V AC, 110 V AC, 24 V DC or 12 V DC coil according to the supply voltage of your control panel. If you are unsure, send the panel details to our WhatsApp line.
Yes. This is a genuine Unox product and all orders are shipped with an invoice.
Orders placed by 3 pm (Istanbul time) on weekdays ship the same day; later orders ship on the next business day.