Unox Kompresör Normalde Kapalı Solenoid Valf (0,5-16 BAR)
What is a Compressor Solenoid Valve?
A compressor solenoid valve is a component that controls the airflow of a compressor. This valve is used to manage the air compression process and regulate air pressure in the compressor. It is generally controlled by an electromagnetic force and can open or close the airflow. Thus, the compressor system can regulate air pressure consistently, increasing or decreasing air pressure as needed.
Where Are Compressor Solenoid Valves Used?
Compressor solenoid valves are commonly used in air compression systems. For example, they can be found in home air conditioners used to control air quality, air regulating systems, and automotive air conditioning units. This valve is also used in air compressors and some pneumatic systems.
Solenoid valves are manufactured in two types: normally closed (valve closed when the coil is energized to open it) and normally open (valve open when coil is energized to close it).
Normally Closed Operation System
A normally closed solenoid valve initially blocks fluid flow. To open the valve, electric current energizes the coil, pulling the core upwards and opening the orifice. This allows the high-pressure fluid to quickly move out through the bypass hole. As this progresses, the pressure inside drops rapidly, creating a pressure difference. Due to this difference, the diaphragm overcomes the spring force and lifts upwards, allowing fluid to pass through and the valve to open. All these happen in a very short time. Our product is designed for optimal efficiency.
General Features
-
Gasket: Viton
-
Sleeve: Stainless Steel
-
Body: Brass
-
Core: Stainless Steel
-
Temperature Range: -10 / +150 °C
-
Coil: Socket type
Recommendations
-
Install the solenoid valve with the coil positioned upwards.
-
Use filters such as strainers before the solenoid valve in the system.
-
For high temperatures, we use more durable diaphragm and gasket materials. Please specify if you require high-temperature resistant diaphragm and gasket when ordering.
Things to Consider When Selecting a Solenoid Valve:
-
The coil must be selected according to the operating voltage (AC-DC). Proper protection and insulation should be ensured based on the application. (The valve opens when electricity is applied and closes when power is cut.)
-
The minimum and maximum pressure values in the line or system where the valve will be used are crucial for valve selection.
-
The nature and temperature of the fluid directly affect valve selection.
-
The direction of fluid flow and the arrow marked on the valve body must be aligned during installation.
-
Since the solenoid valve does not function as a check valve, fluid may flow backward under reverse pressure. In such cases, installing a check valve after the solenoid valve is advisable.
-
The line where the valve is installed must be free from dirt and debris.
Specifications
| Size | Model | Orifice (mm) | Pressure |
|---|---|---|---|
| 1/8" | KOM 1500 | 1 | 100 Bar |
| 1/8" | KOM 1500 | 1.8 | 60 Bar |
| 1/8" | KOM 1500 | 2.5 | 40 Bar |
| 1/8" | KOM 1500 | 3 | 20 Bar |
| 1/8" | KOM 1500 | 4 | 10 Bar |
| 1/8" | KOM 1500 | 5 | 5 Bar |
| 1/8" | KOM 1500 | 8 | 1 Bar |
| 1/4" | KOM 1501 | 1 | 100 Bar |
| 1/4" | KOM 1501 | 1.8 | 60 Bar |
| 1/4" | KOM 1501 | 2.5 | 40 Bar |
| 1/4" | KOM 1501 | 3 | 20 Bar |
| 1/4" | KOM 1501 | 4 | 10 Bar |
| 1/4" | KOM 1501 | 5 | 5 Bar |
| 1/4" | KOM 1501 | 8 | 1 Bar |
| 3/8" | KOM 1502 | 12 | 0.5-16 Bar |
| 1/2" | KOM 1503 | 14 | 0.5-16 Bar |
| 3/4" | KOM 1504 | 16 | 0.5-16 Bar |
| 1" | KOM 1505 | 17 | 0.5-16 Bar |